Skip to main content

Erratum: A reference bacterial genome dataset generated on the MinIONTM portable single-molecule nanopore sequencer

The Original Article was published on 20 October 2014

Recently we noticed that we could not reproduce Figure three (Figure 1 here) while analysing this data as part of a new experiment [1]. This was due to a modification to the script used for extracting sequence alignment profiles from the dataset [2]. On further investigation we found that an error in this script had been reported and a fix supplied by an anonymous online contributor on October 27th 2014 via Github [3]. The error prevented mismatches from being properly counted in the calculation of read accuracy (insertions and deletions were). We therefore present updated versions of Figures three (Figure 1 here) and four (Figure 2 here) generated by the corrected script. We are grateful to the anonymous contributor who noticed this error. The manuscript text and tables are unaffected.

Figure 1
figure 1

Kernel density plots showing accuracy for R7 and R7.3 chemistries with two different values for the LAST substitution penalty score.

Figure 2
figure 2

Alignment identity and completeness. Each plot reflects the alignment identity and the proportion of the read aligned for all 2D reads, as well as the underlying template and complement sequences. The top two panels reflect the alignment results for normal and full 2D reads from the R7 flowcell, and the bottom two panels reflect the R7.3 flowcell. Left panels employ a mismatch penalty of 1 and right panels reflect a mismatch penalty of 2. Overall, the lower mismatch penalty increases the identity and fraction of the read that aligned and this effect is greatest for full 2D reads.

We would also like to correct the spelling of Minh Duc Cao in the Acknowledgements section.

We apologise for any inconvenience caused by this error.

References

  1. Quick J, Quinlan AR, Loman NJ. A reference bacterial genome dataset generated on the minionâ„¢ portable single-molecule nanopore sequencer. GigaScience. 2014; 3:22.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Quinlan AR. 2014. https://github.com/arq5x/nanopore-scripts/blob/master/count-errors.py.Github

  3. Anon. 2014. https://github.com/arq5x/nanopore-scripts/pull/1.Github

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nicholas J Loman.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Quick, J., Quinlan, A.R. & Loman, N.J. Erratum: A reference bacterial genome dataset generated on the MinIONTM portable single-molecule nanopore sequencer. GigaSci 4, 6 (2015). https://doi.org/10.1186/s13742-015-0043-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13742-015-0043-z