Skip to main content

Table 2 Accuracy of six error correction methods on 100 million simulated reads, by expression level of transcripts. k-mer sizes used are those in Table 1

From: Rcorrector: efficient and accurate error correction for Illumina RNA-seq reads

Program

Recall

Precision

F-score

Low expression

   

SEECER

32.78

90.54

48.14

HShrec

24.77

0.81

1.56

Coral

31.88

64.60

42.69

Musket

13.88

33.94

19.71

BFC

25.18

58.37

35.19

Rcorrector

39.40

86.62

54.16

Medium expression

   

SEECER

86.58

97.05

91.51

HShrec

70.57

19.57

30.64

Coral

89.07

85.12

87.05

Musket

72.02

92.16

80.86

BFC

89.12

96.88

92.84

Rcorrector

87.73

99.66

93.31

High expression

   

SEECER

87.39

96.90

91.90

HShrec

69.22

41.67

52.02

Coral

47.59

85.17

61.06

Musket

80.50

98.53

88.61

BFC

77.47

98.35

86.67

Rcorrector

89.42

99.91

94.37

  1. Best performers are highlighted in italic