Table 3 Linear programming formulation and solution statistics for the TG119 case, all five beams used

From: Shared data for intensity modulated radiation therapy (IMRT) optimization research: the CORT dataset

Objective

min (mean Core + mean BODY)

Constraints

OuterTarget >= 1

 

OuterTarget <= 1.2

 

Core <= 1.2

Results

mean Core = 0.2489

 

mean BODY = 0.1021

  1. All doses in Gy.